Manufacturer:
TimeMark
Part Number:
2500-415
Series:
Model 2500
Description:
3-Phase Monitor Relay • Type: Reversal, Loss, Unbalance, Voltage • Coil Voltage: 415 VAC • Contact Configuration: SPDT (1 Form C) • Mounting: Base • Contact Current: 30 Amps
RoHS un-known
Ordering Information
Availability
Availability:
0 In Stock
Minimum Order Qty:
1
Factory Packing Qty:
0
Pricing
1 - 4
$ 671.26
5 - 9
$ 619.63
10 - 24
$ 575.37
25 +
$ 537.02
Order
Quantity
Overview
Specification
Drawings
The Models 2500 and 2501 3-Phase Monitors are designed to continuously monitor the voltages of a 3-phase power distribution system for abnormal conditions. The monitors feature solid-state voltage and phase angle sensing circuits which drive a SPDT electromechanical output relay. A neutral connection is not required with either the Model 2500 or 2501. This allows each model to be connected to any three phase WYE or DELTA configured power distribution system.
When the correct voltage and phase sequence is applied to a specified Model 2500, the output relay will not energize. An under voltage, phase reversal, phase unbalance or phase loss condition will cause the output relay to energize, even if regenerated voltage is present. Complete power loss will not cause Model 2500 to trip.
When the correct voltage and phase sequence is applied to a specified Model 2501, the output relay will energize. An under voltage, phase reversal, phase unbalance, or phase loss condition will cause the output relay to de-energize.
Each option on the Model 2500 or 2501 is adjustable throughout it’s operating range. The adjustment pots and LED indicators for VOLTAGE ADJUST, UNBALANCE ADJUST and TIME DELAY are mounted on the front of the unit, for easy access.
Seven versions of both the Model 2500 and the Model 2501 cover voltage ranges from 120 to 600 VAC. All models are UL Listed to U.S. and Canadian safety standards.
Features
Monitors for Phase Loss or Reversal, Low Voltage or Voltage Unbalance
Automatic Reset
Heavy Duty Output Contacts
UL Listed to U.S. and Canadian Safety Standards
Main Category
Monitors
Sub Category
Phase Monitor Relay
Type
Reversal, Loss, Unbalance, Voltage
Coil Voltage
415 VAC
Contact Configuration
1C SPDT
Mounting
Base
Contact Current
30 Amps
Function
output relay will energize when a fault is detected
Adjustment Range
290-394V
Frequency
50/60 Hz
Unbalance adj range
2 to 10% per NEMA specifications
Trip Delay adj range
1 to 10 seconds (1 sec increments)
Power Consumption
4.5W per phase
Repeat Accuracy
± 1% of full scale
Reset Time
150 msec nominal
Reset Type
Automatic
Dead Band
2% of full scale
Output Contacts
SPDT 30 amps at 28VDC/300VAC 50/60 Hz, 5 amps at 480/600VAC 50/60 Hz 0.75 PF
Operating Temp
- 4º to +131º F
Humidity Tolerance
0-97% without condensation
Enclosure Material
ABS plastic
Weight
2 lbs. 5 oz.
Agency Approval
UL Listed to U.S. and Canadian safety standards