TimeMark Corporation Logo


Model Image Type aaaaa
Model 16-1-X-X
TimeMark Voltage and Frequency Monitor Model 16-1-X-X Over and/or Under Voltage Monitor The Model 16-1-X-X protects equipment from Over, Under, Over/Under voltage or rapid cycling conditions that can damage valuable equipment. Trip and restart delays are adjustable, or can be disabled. Input voltage ranges are 12-30 VAC/VDC or 30-277 VAC/VDC. The 8-pin plug-in has 2 SPDT relays, while the surface mount case has 1 SPDT relay. See Ordering Information for details. 8-pin plug-in versions require an 8-pin socket, such as Time Mark’s Model 51X120. A proprietary microcontroller-based sensing circuit deenergizes the relay(s) after the trip delay (if enabled) upon detection of harmful voltage conditions. The relay(s) will energize after power line conditions return to an acceptable level and the restart delay time has expired (if enabled). Trip delays can be added to avoid nuisance tripping while restart delays can be used to stagger the startup of equipment or protect compressors. Time Mark’s proprietary microcontroller-based design offers maximum flexibility with an easy to use interface.
Model 160B(R)
TimeMark Voltage and Frequency Monitor Model 160B(R) Over or Under Voltage Monitor The Model 160B(R) Voltage Sensor is a single set-point voltage sensor. Input voltages above the set-point cause the output contacts to energize. Input voltages below the set-point cause the output contacts to de-energize. The dead band between pull-in and drop-out is less than 1%.
Model 26
TimeMark Voltage and Frequency Monitor Model 26 True RMS Over/Under Voltage Monitor Model 26 True RMS Voltage Monitor has a display that shows the voltage with an accuracy of +/- 0.5%. The display is updated every second and re-initialized every 30 seconds.
Model 2601
TimeMark Voltage and Frequency Monitor Model 2601 Under-Voltage Monitor The Model 2601 is a single-set-point under-voltage monitor. Input voltages above set-point will cause the output contact to energize and LED indicator to illuminate. Input voltages below the set-point will cause the output contact to de-energize and extinguish the LED indictor.
Model 2602
TimeMark Voltage and Frequency Monitor Model 2602 Under Voltage Monitor The Model 2602 Voltage Sensor is a rapid response device for sensing a low voltage condition on 120 VAC, 60 Hz, single phase power systems. Operating power is drawn from the same line being monitored.
Model 2621
TimeMark Voltage and Frequency Monitor Model 2621 Pick Up/Drop Out Voltage Monitor The Model 2621 dual set point voltage monitor is designed to monitor single phase equipment. The Normal LED indicates the relay is ENERGIZED. Toggle switch settings are as follows:
Off lo: Relay de-energizes at Lo Trip / Relay energizes at Hi Trip
On lo: Relay energizes at Lo Trip / Relay de-energizes at Hi Trip
Model 2628
TimeMark Voltage and Frequency Monitor Model 2628 Over or Under Voltage Monitor The Model 2628 AC/DC Voltage Monitor is designed to continuously monitor any AC or DC voltage from 15 to 260 volts.
Model 2629
TimeMark Voltage and Frequency Monitor Model 2629 Over or Under Voltage Monitor The Model 2629 AC/DC Voltage Monitor is designed to continuously monitor any AC or DC voltage from 15 to 260 volts.
Model 268
TimeMark Voltage and Frequency Monitor Model 268 Voltage Band Monitor The Model 268 Over & Under Voltage Monitor is designed to ensure that the monitored operating voltage remains within a 120 VAC band. This device uses a dual op-amp comparator circuit to achieve stable and repeatable trip set-points.
Model 2681
TimeMark Voltage and Frequency Monitor Model 2681 Voltage Band Monitor The Model 2681 Voltage Band Monitor is a dual set-point voltage monitor. Input voltages between the upper and lower set-points will cause the output contacts to pull in (contacts 1 & 3 closed) and the LED indicator to illuminate. Input voltages above or below the set-points will cause the output contacts to drop out (contacts 1 & 4 closed) and extinguish the LED indicator.
Model 29
TimeMark Voltage and Frequency Monitor Model 29 Frequency Monitor Model 29 Frequency Monitor has a display that shows the frequency with an accuracy of +/- 0.5%. The display is updated every second and re-initialized every 30 seconds. This unit has a user selectable relay option for High-Low or DPDT. It can also be user-selected to energize on fault or de-energize on fault. The user can select automatic or manual restart on the Model 29. The SG version of the Model 29 has silver with gold flash contacts for low current applications Model 29 Frequency Monitor can be restored to factory defaults.
Model 292
TimeMark Voltage and Frequency Monitor Model 292 Frequency Monitor The Model 292 Frequency Monitor is designed to monitor power line frequency. It is intended for systems where line frequency variations will cause improper operation of electrical equipment. A solid-state sensing circuit drives an internal electromechanical relay which is energized when the line frequency is correct. Operating power is drawn from the same line being monitored.
Model 260
TimeMark Voltage and Frequency Monitor Model 260 Over or Under Voltage Monitor The Model 260 Voltage Sensor is a single set-point voltage sensor. Input voltages above the set-point cause the output contacts to energize (contacts 1 & 8 closed). Input voltages below the set-point cause the output contacts to de-energize (contacts 1 & 2 closed). The dead band between pull-in and drop-out is less than 2%.