Specifications

Operating Voltage, Power Input (Single Phase) 120VAC; Euro 230VAC
(Double Phase) 120/240VAC
(Three Phase) 120/208VAC; 230/415 VAC
CAN Bus Operating Voltage 9 VDC – 16 VDC, 15 VDC Nominal
Load Equivalence Number 1
Dimensions 8 Position: 12.36” X 11.63” X 4.98”
13 Position: 20.66” X 13.39” X 4.98”
CAN Bus Connectors Two (2) Micro-C Male
Orientation Vertical Position (not flat)
Operating Temperature -40°C to +55°C
Weight with breakers A3000-08: 16 lbs. (7.25 kg)
A3000-13: 22 lbs. (9.98 kg)
A3000-19: 29 lbs. (13.15 kg)
NMEA 2000 Category B
Lloyd’s Register Lloyd’s Type Approved, Test Specification #1, Env 2
CE IEC 60533 Electrical and Electronic Installations in Ships
IEC 60945 Maritime Navigation and Radio Communication Equipment and Systems